Technical documentation, installation, and operation.
Check the most common malfunctions along with their causes and solutions.
Malfunctions and solutions for industrial RO systems.
Cause: Membrane clogged.
Solution: Replace membrane.
Cause: Solenoid valve between filters and pump remains closed. Solenoid valve coil burned out.
Solution: Replace the solenoid valve.
Cause: Vane pump worn out.
Solution: Replace vane pump.
Cause: Display glass fuse blown.
Solution: Replace glass fuse (back of display).
Cause: Motor thermal protection in the electrical cabinet has been triggered.
Solution: Reset thermal protection in the electrical cabinet.
Cause: The low-pressure switch is set too high.
Solution: Adjust the low-pressure switch to a lower setting.
Solution: Check if 'Full' lights up on the display and check the float switch. If necessary, connect the green wires together.
Malfunctions and solutions for the RO 600 GPD Commercial version.
Cause: Membrane clogged.
Solution: Replace membrane.
Cause: Display glass fuse blown, or short circuit in the inverter, or short circuit in the coil of the blue solenoid valve at the top right.
Solution: Check the glass fuse, check the inverter, and check the solenoid valve coil. Replace these if necessary.
Cause: Coil of the blue solenoid valve (top right) burned out.
Solution: Replace the solenoid valve.
Answers to practical questions regarding the use, maintenance, and performance of RO systems.
This depends on water quality and intensity of use. In many situations, pre-filters are checked periodically and replaced preventatively according to the maintenance schedule. Under normal conditions and average use, this is every 2-3 months.
At lower water temperatures, the output of an RO system decreases. This is normal and must be taken into account when dimensioning the system. It is not effective to compensate using the control knob, as this will result in a clogged membrane.
A higher value may indicate contaminated or worn membranes, incorrect settings, deviations in water pressure and operating conditions, or the incorrect installation of a new membrane.
Our RO Industrial systems are designed for continuous production. The compact RO 600 Commercial has a cycle of a maximum of 10 hours of production followed by one hour of rest.
This depends on usage, water quality, and maintenance. A decrease in production or deteriorated water quality may be an indication that inspection or replacement is required.